Ferrite Number vs Ferrite Percentage in Stainless Steel Welds

Quick answer. Ferrite Number (FN) and ferrite volume percentage describe related measurements, but they are not interchangeable units. FN is a standardized magnetic measurement scale used for stainless steel weld metal. A percentage must identify how the ferrite fraction was determined. Keep the reported method, unit and acceptance requirement together before deciding whether a result is acceptable.

Two results that need different interpretation

Report entry What to establish
Ferrite Number, FN The magnetic calibration procedure, specimen condition and measurement locations.
Ferrite percentage Whether the value is a metallographic volume-fraction estimate or an instrument-reported percentage under an agreed procedure.
Predicted ferrite The prediction model and input chemistry. A calculated result does not establish the measured value of the finished weld.

A report stating 8 FN should remain 8 FN. Relabeling it as 8% without an applicable, agreed relationship changes its meaning. Approximate agreement at low ferrite levels does not establish a universal conversion for other compositions or higher readings.

Weld metal and base material have different test boundaries

ISO 8249 addresses FN determination and instrument calibration for austenitic and duplex stainless steel weld metals. Its stated method is not intended for measuring ferrite in cast, forged or wrought base-material samples. A duplex bar or plate requirement therefore needs a procedure appropriate to that material, rather than an automatic reference to a weld-metal method.

Metallographic point counting under ASTM E562 provides a statistical estimate of the volume fraction of an identifiable phase from prepared sections. Sampling, phase identification and the agreed procedure matter when comparing that result with a magnetic reading.

Interpretation note. Confirm the applicable standard edition and project requirements. A measurement-method reference alone does not establish a universal acceptable ferrite range.

Why readings may differ

Magnetic induction responds to magnetizable constituents. Depending on the material condition, deformation martensite can affect the response; the instrument does not automatically distinguish it from ferrite. Curvature, thin sections, surface roughness and probe placement can also affect readings. Review these influences before concluding that the material itself has changed.

Read the report in this order

  1. Identify the specimen. Check grade, heat or component identification, weld or base-material location, and processing condition.
  2. Identify the method and unit. Keep FN, percentage and calculated predictions clearly separated.
  3. Review measurement coverage. Check locations, individual readings, repeat measurements and the reported result required by the procedure.
  4. Apply the correct acceptance requirement. Compare the result with the applicable product, welding or project specification using the required method and unit.

Questions about ferrite reports

Can a hand magnet replace the test?

Answer: No. A qualitative attraction check does not provide a calibrated FN or a documented ferrite volume fraction.

Does the same FN suit every stainless weld?

Answer: No. Alloy, weld procedure and service requirements determine the applicable limits. Do not adopt a general internet range as the acceptance criterion.

What should a material inquiry include?

Answer: Identify the product form, grade, condition and governing specification. If ferrite verification is required, state the method, unit, sampling locations and acceptance requirement for review before ordering.

Review the product form and inspection requirements for your duplex stainless steel application.